DESIGN-BUILD
BEQ Replacements (Buildings 1686 and 1687)
Andrews Air Force Base
Camp Springs, Maryland
Three-story, 3,960 square meter (42,600 square foot) cast-in-place concrete design/build bachelor enlisted quarters facilities with exterior corridors. The projects incorporate the Department of Defense Anti-Terrorism/Force Protection Requirements for preventing a progressive collapse if a column, beam or exterior wall panel were to be destroyed by an external terrorism event.
bus03_top.gif
Holbert Apple Associates, Inc.
Structural Engineers
haa_-_may_2009016002.jpg
Swain Annex
Marine Corps Base, Mainside
Quantico, Virginia
Three-story, approximately 35,000 gross square foot structural steel framed design/build office building and a one-story enclosed walkway. The office building structure consists of structural steel framing (wide flange columns, composite steel floor framing and wide flange beam and girder attic framing supporting light gauge steel roof trusses and metal decking) designed for the appropriate code and anti-terrorism progressive collapse requirements. The encosed walkway is constructed of steel tube columns, wide flange beams and light gauge metal roof trusses. The foundations are continuous strip footings and a 5" slab-on-grade.
Home
Firm Overview
Associates
Portfolio
Professional Services
Contact Us
Renovations/
Additions
Design-Build
Parking Structure
Rehabilitation
Principals
Residential
Office/Retail
Hotels
haa_-_may_2009016001.jpg